Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Sci Total Environ ; 923: 171189, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38447726

RESUMO

Antifungal resistance has emerged as a significant health concern with increasing reports of resistant variants in previously susceptible species. At present, little is known about occupational exposure to antifungal-resistant fungi. This study aimed to investigate Danish workers' occupational exposure to airborne fungi resistant to first-line treatment drugs. A retrospective study was performed on a unique collection of personal exposure samples gathered over a twenty-year period from Danish working environments, in sectors including agriculture, animal handling, waste management, and healthcare. A total of 669 samples were cultivated at 37 °C and fungal colonies were identified using MALDI-TOF MS. Subsequently, identification was confirmed by amplicon sequencing the genes of calmodulin and beta-tubulin to unveil potential cryptic species. Infectious fungi (495 isolates from 23 species) were tested for resistance against Itraconazole, Voriconazole, Posaconazole, and Amphotericin B. Working environments were highly variable in the overall fungal exposure, and showed vastly different species compositions. Resistance was found in 30 isolates of the species Aspergillus fumigatus (4 of 251 isolates), A. nidulans (2 of 13), A. niger complex (19 of 131), A. versicolor (3 of 18), and A. lentulus (2 of 2). Sequence analysis revealed several cryptic species within the A. niger complex including A. tubingensis, A. luchuensis, and A. phoenicis. Among the resistant A. fumigatus isolates, two contained the well-described TR34/L98H mutation in the cyp51A gene and promoter region, while the remainder harbored silent mutations. The results indicate that the working environment significantly contributes to exposure to resistant fungi, with particularly biofuel plant workers experiencing high exposure. Differences in the prevalence of resistance across working environments may be linked to the underlying species composition.


Assuntos
Antifúngicos , Proteínas Fúngicas , Antifúngicos/farmacologia , Estudos Retrospectivos , Proteínas Fúngicas/genética , Fungos , Itraconazol , Aspergillus fumigatus , Testes de Sensibilidade Microbiana , Azóis
2.
Front Public Health ; 12: 1332078, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38420031

RESUMO

Objective: Children who start in day-care have 2-4 times as many respiratory infections compared to children who are cared for at home, and day-care staff are among the employees with the highest absenteeism. The extensive new knowledge that has been generated in the COVID-19 era should be used in the prevention measures we prioritize. The purpose of this narrative review is to answer the questions: Which respiratory viruses are the most significant in day-care centers and similar indoor environments? What do we know about the transmission route of these viruses? What evidence is there for the effectiveness of different non-pharmaceutical prevention measures? Design: Literature searches with different terms related to respiratory infections in humans, mitigation strategies, viral transmission mechanisms, and with special focus on day-care, kindergarten or child nurseries, were conducted in PubMed database and Web of Science. Searches with each of the main viruses in combination with transmission, infectivity, and infectious spread were conducted separately supplemented through the references of articles that were retrieved. Results: Five viruses were found to be responsible for ≈95% of respiratory infections: rhinovirus, (RV), influenza virus (IV), respiratory syncytial virus (RSV), coronavirus (CoV), and adenovirus (AdV). Novel research, emerged during the COVID-19 pandemic, suggests that most respiratory viruses are primarily transmitted in an airborne manner carried by aerosols (microdroplets). Conclusion: Since airborne transmission is dominant for the most common respiratory viruses, the most important preventive measures consist of better indoor air quality that reduces viral concentrations and viability by appropriate ventilation strategies. Furthermore, control of the relative humidity and temperature, which ensures optimal respiratory functionality and, together with low resident density (or mask use) and increased time outdoors, can reduce the occurrence of respiratory infections.


Assuntos
COVID-19 , Infecções Respiratórias , Criança , Humanos , Pandemias , Aerossóis e Gotículas Respiratórios , Infecções Respiratórias/epidemiologia , Infecções Respiratórias/prevenção & controle , COVID-19/epidemiologia , COVID-19/prevenção & controle , Adenoviridae
3.
Ann Work Expo Health ; 68(1): 58-77, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-37995292

RESUMO

This cross-sectional study aims to obtain knowledge about workers' exposure to airborne dust, bacterial and fungal species, endotoxin, biofilm formation, and hydrogen sulfide (H2S) in drilling waste treatment plants. In total, 408 full-shift personal samples, 66 work areas, 40 drilling waste, and reference (outdoor air and seawater) samples were analyzed. Some workers were exposed to high levels of endotoxin (207 EU/m3), bacteria (3.8 × 104 colony forming units (CFU)/m3 and 9.8 × 104 DNA copies/m3), or fungi (1.4 × 107 CFU/m3 and 3,600 copies/m3). The exposure levels to endotoxin, bacteria, and peaks of H2S were dependent on the treatment technique. All types of drilling waste contained large concentrations of bacteria compared to the seawater references. Elevated concentrations of airborne bacteria were found close to drilling waste basins. In total, 116, 146, and 112 different bacterial species were found in workers' exposure, work areas, and the drilling waste, respectively. An overlap in bacterial species found in the drilling waste and air (personal and work area) samples was found. Of the bacterial species found, 49 are classified as human pathogens such as Escherichia coli, Enterobacter cloacae, and Klebsiella oxytoca. In total, 44 fungal species were found in the working environment, and 6 of these are classified as human pathogens such as Aspergillus fumigatus. In conclusion, across the drilling waste treatment plants, human pathogens were present in the drilling waste, and workers' exposure was affected by the drilling waste treated at the plants with elevated exposure to endotoxin and bacteria. Elevated exposure was related to working as apprentices or chemical engineers, and working with cleaning, or slop water, and working in the daytime.


Assuntos
Poluentes Ocupacionais do Ar , Sulfeto de Hidrogênio , Exposição Ocupacional , Humanos , Exposição Ocupacional/análise , Endotoxinas/análise , Estudos Transversais , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Microbiologia do Ar , Monitoramento Ambiental , Fungos , Bactérias
4.
Chemosphere ; 345: 140449, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37839747

RESUMO

In a recent estimate, 96 million tons of hazardous waste were produced in the European Union, most of which were handled among the member states. Organophosphate esters (OPEs) are applied as flame retardants and plasticizers and are present in many products, e.g., electronics, which end up in the hazardous waste stream upon disposal. Given the growing body of information suggesting potential adverse health effects of OPEs, waste recycling workers who handle hazardous waste could potentially be at risk of elevated exposure to these chemicals. Using silicone wristbands, we evaluated OPE exposure among waste recycling workers who handled hazardous waste and compared their exposure to that of administrative workers from the same waste companies. Wristbands were extracted and analyzed for six OPEs, which were all detected in >75% of wristbands. Overall, the sum of tris(2-chloroisopropyl) phosphate (∑TCIPP) isomers was the most abundant OPE across all wristbands collected within the study. In general, the sum of tri(methyl phenyl) phosphate isomers (∑TMPP) was elevated for all waste workers (10ß = 7.9), whereas tri-n-butyl phosphate (TnBP), tris(1,3-dichloroisopropyl) phosphate (TDCIPP), and ∑TMPP were 3-12 times higher among those specifically handling electronic and hazardous waste compared to the administrative workers (p < 0.05). Repeated wristband measurements from the same worker had fair to good consistency in OPE concentrations (intraclass correlation coefficients = 0.54-0.77), except for the two most volatile chlorinated OPEs. Taken together, our results suggest that waste recycling workers who handle electronic and hazardous waste have significantly elevated exposure to OPEs, and efforts to reduce these exposures should be considered.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Retardadores de Chama , Humanos , Silicones , Organofosfatos , Fosfatos , Retardadores de Chama/análise , Resíduos Perigosos , Ésteres , Dinamarca , Monitoramento Ambiental
5.
Int J Hyg Environ Health ; 253: 114240, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37633050

RESUMO

This study assessed microorganisms in personal inhalable work air samples aiming to identify potential human pathogens, and correlate exposure to adverse health outcomes in waste workers. Full-shift personal exposure was measured in six different waste sorting plants. Microbial concentrations in inhalable air samples were analysed using MALDI-TOF MS for cultivable, and next generation sequencing (NGS) for non-cultivable microorganisms. Concentrations of bacterial and fungal CFUs varied substantially within and between waste sorting plants, ranging from no identifiable organisms to a maximum concentration in the order of 105 CFU/m3. Bacillus and Staphylococcus were among the most abundant bacterial genera, whilst fungal genera were dominated by Aspergillus and Penicillium. Approximately 15% of all identified species were human pathogens classified in risk group 2, whereas 7% belonged to risk group 1. Furthermore, significant correlations between concentrations of fungi in risk group 1 and self-reported adverse symptoms, such as wheezing were identified in exposed workers. The combination of culture-based methods and NGS facilitated the investigation of infectious microbial species with potential pathophysiological properties as well as non-infectious biological agents in inhalable work air samples and thereby contributed to the risk assessment of occupational exposure in waste sorting.


Assuntos
Exposição Ocupacional , Humanos , Medição de Risco , Autorrelato , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
6.
Waste Manag ; 167: 173-182, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37269581

RESUMO

Biowaste pretreatment plants have been built within the last years in Denmark in order to recycle pre-sorted biowaste from houses, restaurants, and industry. We investigated the association between exposure and health at six biowaste pretreatment plants (visited twice) across Denmark. We measured the personal bioaerosol exposure, took blood samples, and administered a questionnaire. Thirty-one persons participated, 17 of them twice, resulting in 45 bioaerosol samples, 40 blood samples, and questionnaire answers from 21 persons. We measured exposure to bacteria, fungi, dust, and endotoxin, the total inflammatory potential of the exposures, and serum levels of the inflammatory markers serum amyloid A (SAA), high sensitivity C-reactive protein (hsCRP), and human club cell protein (CC16). Higher exposures to fungi and endotoxin were found for workers with tasks inside the production area compared to workers with main tasks in the office area. A positive association was found between the concentration of anaerobic bacteria and hsCRP and SAA, whereas bacteria and endotoxin were inversely associated with hsCRP and SAA. A positive association between hsCRP and the fungal species Penicillium digitatum and P. camemberti were found, whereas an inverse association between hsCRP and Aspergillus niger and P. italicum were found. Staff with tasks inside the production area reported more symptoms of the nose than those working in the office area. To conclude, our results indicate that workers with tasks inside the production area are exposed to elevated levels of bioaerosols, and that this may affect workers' health negatively.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Humanos , Exposição Ocupacional/análise , Poluentes Ocupacionais do Ar/análise , Proteína C-Reativa , Monitoramento Ambiental/métodos , Bactérias , Endotoxinas/análise , Plantas , Inflamação/induzido quimicamente , Poeira/análise , Microbiologia do Ar , Fungos , Aerossóis
7.
Ann Work Expo Health ; 67(7): 831-846, 2023 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-37300561

RESUMO

Indoor microbial exposure may cause negative health effects. Only little is known about the occupational microbial exposure in nursing homes and the factors that influence the exposure. The exposure in nursing homes may be increased due to close contact with elderly persons who may carry infectious or antimicrobial-resistant microorganisms and due to handling of laundry, such as used clothing and bed linen. We investigated the microbial exposure in 5 nursing homes in Denmark, by use of personal bioaerosol samples from different groups of staff members taken during a typical working day, stationary bioaerosol measurements taken during various work tasks, sedimented dust samples, environmental surface swabs, and swabs from staff members' hands. From the samples, we explored bacterial and fungal concentrations and species composition, endotoxin levels, and antimicrobial resistance in Aspergillus fumigatus isolates. Microbial concentrations from personal exposure samples differed among professions, and geometric means (GM) were 2,159 cfu/m3 (84 to 1.5 × 105) for bacteria incubated on nutrient agar, 1,745 cfu/m3 (82 to 2.0 × 104) for bacteria cultivated on a Staphylococcus selective agar, and 16 cfu/m3 air for potential pathogenic fungi incubated at 37 °C (below detection limit to 257). Bacterial exposures were elevated during bed making. On surfaces, the highest bacterial concentrations were found on bed railings. The majority of bacterial species found were related to the human skin microflora, such as different Staphylococcus and Corynebacterium species. Endotoxin levels ranged from 0.02 to 59.0 EU/m3, with a GM of 1.5 EU/m3. Of 40 tested A. fumigatus isolates, we found one multiresistant isolate, which was resistant towards both itraconazole and voriconazole, and one isolate resistant towards amphotericin B. In conclusion, we give an overview of the general microbial exposure in nursing homes and show that microbial exposures are higher for staff with more care and nursing tasks compared with administrative staff.


Assuntos
Poluentes Ocupacionais do Ar , Anti-Infecciosos , Exposição Ocupacional , Humanos , Idoso , Exposição Ocupacional/análise , Endotoxinas/análise , Ágar , Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental , Bactérias , Staphylococcus
8.
Ann Work Expo Health ; 67(7): 816-830, 2023 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-37191914

RESUMO

INTRODUCTION: Recycling of domestic waste and a number of employees in the recycling industry is expected to increase. This study aims to quantify current exposure levels of inhalable dust, endotoxin, and microorganisms and to identify determinants of exposure among recycling workers. METHODS: This cross-sectional study included 170 full-shift measurements from 88 production workers and 14 administrative workers from 12 recycling companies in Denmark. The companies recycle domestic waste (sorting, shredding, and extracting materials from waste). We collected inhalable dust with personal samplers that were analysed for endotoxin (n = 170) and microorganisms (n = 101). Exposure levels of inhalable dust, endotoxin, and microorganisms and potential determinants of exposure were explored by mixed-effects models. RESULTS: The production workers were 7-fold or higher exposed to inhalable dust, endotoxin, bacteria, and fungi than the administrative workers. Among production workers recycling domestic waste, the geometric mean exposure level was 0.6 mg/m3 for inhalable dust, 10.7 endotoxin unit (EU)/m3 for endotoxin, 1.6 × 104 colony forming units (CFU)/m³ of bacteria, 4.4 × 104 CFU/m³ of fungi (25 °C), and 1.0 × 103 CFU/m³ of fungi (37 °C). Workers handling paper or cardboard had higher exposure levels than workers handling other waste fractions. The temperature did not affect exposure levels, although there was a tendency toward increased exposure to bacteria and fungi with higher temperatures. For inhalable dust and endotoxin, exposure levels during outdoor work were low compared to indoor work. For bacteria and fungi, indoor ventilation decreased exposure. The work task, waste fraction, temperature, location, mechanical ventilation, and the company size explained around half of the variance of levels of inhalable dust, endotoxin, bacteria, and fungi. CONCLUSION: The production workers of the Danish recycling industry participating in this study had higher exposure levels of inhalable dust, endotoxin, bacteria, and fungi than the administrative workers. Exposure levels of inhalable dust and endotoxin among recycling workers in Denmark were generally below established or suggested occupational exposure limits (OEL). However, 43% to 58% of the individual measurements of bacteria and fungi were above the suggested OEL. The waste fraction was the most influential determinant for exposure, and the highest exposure levels were seen during handling paper or cardboard. Future studies should examine the relationship between exposure levels and health effects among workers recycling domestic waste.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Humanos , Exposição Ocupacional/análise , Endotoxinas/análise , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Estudos Transversais , Monitoramento Ambiental , Exposição por Inalação/análise , Bactérias , Fungos , Dinamarca
9.
UCL Open Environ ; 5: e056, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37229345

RESUMO

The aim of this study is to obtain knowledge about which cultivable bacterial species are present in indoor air in homes, and whether the concentration and diversity of airborne bacteria are associated with different factors. Measurements have been performed for one whole year inside different rooms in five homes and once in 52 homes. Within homes, a room-to-room variation for concentrations of airborne bacteria was found, but an overlap in bacterial species was found across rooms. Eleven species were found very commonly and included: Acinetobacter lowffii, Bacillus megaterium, B. pumilus, Kocuria carniphila, K. palustris, K. rhizophila, Micrococcus flavus, M. luteus, Moraxella osloensis and Paracoccus yeei. The concentrations of Gram-negative bacteria in general and the species P. yeei were significantly associated with the season with the highest concentrations in spring. The concentrations of P. yeei, K. rhizophila and B. pumilus were associated positively with relative humidity (RH), and concentrations of K. rhizophila were associated negatively with temperature and air change rate (ACR). Micrococcus flavus concentrations were associated negatively with ACR. Overall, this study identified species which are commonly present in indoor air in homes, and that the concentrations of some species were associated with the factors: season, ACR and RH.

10.
Water Res ; 231: 119625, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36680819

RESUMO

Work in wastewater treatment plants (WWTPs) can be associated with exposure to airborne microorganisms and endotoxin from the working environment. The aim of this study was to obtain knowledge about whether serum levels of the markers of systemic inflammation, C-reactive protein (CRP) and serum amyloid A (SAA), are associated with personal exposure to endotoxin, measured using the Limulus (endotoxinLimulus) and the rFC (endotoxinrFC) assays, as well as bacteria and fungi in a cohort of WWTP workers. Exposure and blood samples were collected for 11 workers over one year. Exposure to endotoxinLimulus-day and endotoxinrFC-day correlated significantly (r = 0.80, p<0.0001, n = 104), but endotoxinLimulus-day was 4.4 (Geometric mean (GM) value) times higher than endotoxinrFC-day (p<0.0001). The endotoxinLimulus-day, endotoxinrFC-day, bacteria, and fungal exposure as well as serum levels of CRP-day (GM=1.4 mg/l) and SAA-day (GM=12 mg/l) differed between workers. Serum levels of SAAday correlated significantly with CRPday (r = 0.30, p = 0.0068). The serum levels of CRPday were associated significantly with exposure to endotoxinLimulus-day. Exposure, SAA and CRP data were also analyzed as av. of each season, and SAAseason was associated positively and significantly with endotoxinLimulus-season and endotoxinrFC-season and negatively with fungalseason exposure. In conclusion, CRPday was associated with the endotoxinLimulus-day and SAAseason with endotoxinLimulus-season and endotoxinrFC-season exposure. Thus, we hereby document that WWTP workers are exposed to airborne endotoxin which seems to have a negative impact on their health.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Purificação da Água , Humanos , Endotoxinas , Exposição Ocupacional/análise , Poluentes Ocupacionais do Ar/análise , Estudos de Coortes , Monitoramento Ambiental/métodos , Bactérias , Biomarcadores , Inflamação , Microbiologia do Ar , Fungos , Poeira/análise
11.
Environ Res ; 216(Pt 2): 114642, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36306875

RESUMO

Pigeon breeding is associated with exposure to airborne microorganisms and endotoxin and with symptoms of the airways. Antibiotic resistance is a threat to human health. Some pigeons participate in national and international indoor exhibitions. This study aims to obtain knowledge about the potential human exposure to dust, endotoxin, fungi, and bacteria including the methicillin-resistant Staphylococcus aureus (MRSA) in a pigeon exhibition in Denmark. In walking areas for visitors, airborne microorganisms in different size fractions able to enter the airways were sampled and following identified. The average concentrations were: 5000 cfu fungi/m3, 1.8 × 104 cfu bacteria/m3, 37 endotoxin units/m3, and 0.18 mg dust/m3 air with the highest concentrations in-between rows with pigeon cages. The fungal species Wallemia sp. and Aspergillus versicolor and the bacterial species S. equorum and S. aureus were found in high concentrations. MRSA spa type t034 described to be associated with livestock was found in the air. Most of the S. aureus was present in the size fraction of 1.1-2.1 µm, which are particles able to enter the human terminal bronchi. In conclusion, fungi, bacteria, and endotoxin, respectively, were found in concentrations 10, 2000, and 200 times higher than outdoor references. The airborne bacteria in the exhibition were mainly species found previously in pigeon coops showing that the pigeons are the sources of exposure. The presence of airborne MRSA in the pigeon exhibition highlights the importance of also considering this environment as a potential place of exchange of resistant bacteria between animals and between animals and humans.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Exposição Ocupacional , Animais , Humanos , Poeira , Columbidae , Endotoxinas/análise , Staphylococcus aureus , Exposição Ocupacional/análise , Bactérias , Fungos , Microbiologia do Ar
12.
Am J Infect Control ; 51(8): 938-957, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36535318

RESUMO

BACKGROUND: Human rhinoviruses (RVs) are the most common cause of acute respiratory tract illness and upper respiratory tract infections, traditionally defined as 'common colds'. Experimental transmission of RV has been studied for more than 50 years. However, there are divergent results as to whether hands and fomites or aerosols constitute the dominant route of transmission in natural settings. METHODS: We have systematically reviewed the literature according to the PRISMA 2020 statement. Searches were run in PubMed and Web of Science until August 2022. Inclusion criteria were original studies of relevance for revealing the route of transmission of rhinovirus in humans. RESULTS: The search yielded 663 results, and 25 studies met the inclusion criteria and were selected for this review. These articles addressing RV transmission routes were assigned to 1 of 3 groups: (1) indirect transmission by fomites and hands, (2) direct transmission via large aerosols (droplets) or small aerosols, or (3) transmission either direct via large aerosols (droplets) or small aerosols and fomite or hands. CONCLUSIONS: We found low evidence, that transmission via hands and fomite followed by self-inoculation is the dominant transmission route in real-life indoor settings. We found moderate evidence, that airborne transmission either via large aerosols or small aerosols is the major transmission route of rhinovirus transmission in real-life indoor settings. This suggests that the major transmission route of RVs in many indoor settings is through the air (airborne transmission).


Assuntos
Resfriado Comum , Humanos , Rhinovirus , Aerossóis e Gotículas Respiratórios , Fômites
13.
Environ Res ; 218: 115040, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36521541

RESUMO

Occupational exposure during waste sorting is associated with several health outcomes. This study obtained knowledge about the impact of work in fully automated waste sorting plants (AWSP; n = 3) vs manual waste sorting plants (MWSP; n = 3) on personal exposure (n = 71) to bioaerosols and exposure-related health effects. Personal full-shift air samples were collected using various filter-based active sampling devices that were placed in the workers' breathing zone. Personal exposure to inhalable and thoracic dust, endotoxin and microorganisms varied considerably between and within types of waste sorting plants (WSP). Workers at AWSP were on average exposed to 0.34 mg/m3 inhalable dust, 0.15 mg/m3 thoracic dust, and 51 EU/m3 endotoxins (geometric mean (GM) levels), whereas GM exposure levels at MWSP were 0.66 mg/m3 for inhalable dust, 0.44 mg/m3 for thoracic dust, and 32 EU/m3 for endotoxins. Exposure to submicronic fungal fragments did not differ between types of plants and ranged from levels below the detection limit (limit of detection, LOD) to levels in the order of 106 fragments/m3. Higher levels of fungal fragments and fungal spores were found at AWSP compared to MWSP with a GM of 2.1 × 105 spores/m3and with a GM of 1.2 × 105 spores/m3, respectively. Actinobacterial spores were found in samples from AWSP only, with exposure levels ranging from 1.9 × 104 to 1.1 × 107 spores/m3. Exposure to microbial DNA varied within and between WSP and was on average in the order of 104 copies/m3 for fungi and 105 copies/m3 for bacteria. Health symptoms, such as sneezing, congested nose and runny nose were significantly more common among exposed workers compared to the unexposed control group.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Humanos , Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental , Exposição por Inalação/análise , Exposição Ocupacional/análise , Endotoxinas , Plantas , Poeira/análise , Microbiologia do Ar
14.
Waste Manag ; 139: 250-257, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34979353

RESUMO

Electrostatic dust cloths have previously been used to study microorganisms in settled dust by placing the cloths horizontally on surfaces (called Electrostatic Dust Collectors, EDC). In this study, we investigate whether the same cloths, henceforth called 'E-Cloths', can be used to study accumulation of microorganisms and endotoxin on workers' clothes. This was studied as current methods have limitations. It was examined for waste collection workers, as their work environment is associated with elevated exposure to microorganisms and endotoxin. Each worker received a kit with a T-shirt with an attached E-Cloth on the front, a instruction letter, and a questionnaire. Workers wore the T-shirts during the next two workdays. Unaffected by waste type collected, it was possible to measure the accumulation of bacteria, fungi, and endotoxin from the work environment on the E-Cloths. Geometric mean concentration of 9 × 106 CFU bacteria/m2, 1 × 107 CFU fungi/m2, and 4 × 104 endotoxin units/m2 were found. In total, 100 different bacterial and 25 fungal species were found. The genus Bacillus (with 18 species) and Brevibacterium aurantiacum were among the dominating bacteria. For fungi, Penicillium brevicompactum, P. commune, Penicillium italicum, and Aspergillus niger were most often found. Importantly, mainly environmental bacteria and fungi had accumulated on the E-Cloths and only few skin-related bacterial species were present, showing that accumulation had happened from the work exposure and not workers' skin. In conclusion, the T-shirts with an E-Cloth can be used as a self-administered method for measurement of accumulation of microorganisms and endotoxin from the work environment on waste collection workers' clothes.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Microbiologia do Ar , Poluentes Ocupacionais do Ar/análise , Vestuário , Poeira/análise , Endotoxinas/análise , Monitoramento Ambiental , Estudos de Viabilidade , Fungos , Humanos , Exposição Ocupacional/análise
15.
Environ Int ; 161: 107112, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35091375

RESUMO

Work clothes may act as a vector for the transport of microorganisms leading to second-hand exposure; however, this has not been studied in work environments. We investigated whether microorganisms accumulate on workers' clothes in environments with elevated microbial exposures, and whether they are transported with the clothes and subsequently resuspended to the air. To study this, we selected waste collection workers and potential transport of bacteria and fungi to waste truck cabs via clothes, and compared the microbial communities within truck cabs, in waste collection workers' personal exposure, and on clean T-shirts worn by the workers. Microbial communities were also investigated for the presence of potentially harmful microorganisms. Results showed that microorganisms accumulated in large quantities (GM = 3.69 × 105 CFU/m2/h for bacteria, GM = 8.29 × 104 CFU/m2/h for fungi) on workers' clothes. The concentrations and species composition of airborne fungi in the truck cabs correlated significantly with the accumulation and composition of fungi on clothes and correlated to concentrations (a trend) and species composition of their personal exposures. The same patterns were not found for bacteria, indicating that work clothes to a lesser degree act as a vector for bacteria under waste collection workers' working conditions compared to fungi. Several pathogenic or allergenic microorganisms were present, e.g.: Klebsiella oxytoca, K. pneumoniae, Proteus mirabilis, Providencia rettgeri, Pseudomonas aeruginosa, and Aspergillus fumigatus, A. glaucus, A. nidulans, A. niger, and various Penicillium species. The potential 'take-home' exposure to these microorganisms are of most concern for immunocompromised or atopic individuals or people with open wounds or cuts. In conclusion, the large accumulation of microorganisms on workers' clothes combined with the overlap between fungal species for the different sample types, and the presence of pathogenic and allergenic microorganisms forms the basis for encouragement of good clothing hygiene during and post working hours.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Microbiologia do Ar , Monitoramento Ambiental , Fungos , Humanos , Exposição Ocupacional/análise
16.
Environ Res ; 204(Pt D): 112404, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34838572

RESUMO

Pigeon breeding is associated with symptoms of the airways. The aim of this study is to illuminate the bacteriological and toxicological characteristics of airborne dust in pigeon coops. Airborne dust was sampled in 31 urban pigeon coops with homing and fancy pigeons, and following the dust was characterized. In total 141 different bacterial species were identified using MALDI-TOF MS, and of these 11 species are classified in risk group 2. Of the cultivable bacteria, Staphylococcus equorum was present in the highest concentration. Microorganisms in the dust were able to form biofilm, and the amount correlated positively with the number of bacteria. Next generation sequencing showed 180 genera with Acinetobacter in highest reads. On average 999 ± 225 ZOTUs were observed per sample with a Shannon-Wiener biodiversity index of 6.17 ± 0.24. Of the identified species the following have previously been suggested as causative agents of extrinsic allergic alveolitis: Alcaligenes faecalis, Bacillus subtilis, Pantoea agglomerans, Sphingobacterium spiritivorum, Thermoactinomyces sp., and Streptomyces albus. Staphylococcus was present on particles with sizes between 1.1 and > 7.0 µm with a geometric mean diameter of particles on 4.7 ± 1.1 µm. Concentrations of airborne endotoxin and dust were elevated compared to references, and the geometric mean concentrations were 102 EU/m3 and 1.07 mg dust/m3, respectively. Upon exposure to the airborne dust human granulocytes produced Reactive Oxidative Species during the first 5 min, and then no further reaction was observed. The concentrations of bacteria in general, Staphylococcus spp., and endotoxin and biodiversity were associated significantly with season, temperature and/or relative humidity, but not with type or density of pigeons. The bacterial composition and biodiversity indices were not affected by type of pigeon. In conclusion, the exposure to bacteria and endotoxin in pigeon houses should not be neglected in the evaluation of causative agents of airways symptoms among pigeon breeders.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Microbiologia do Ar , Poluentes Ocupacionais do Ar/análise , Animais , Columbidae , Estudos Transversais , Poeira/análise , Endotoxinas/análise , Exposição Ocupacional/análise , Medição de Risco
17.
Waste Manag ; 131: 237-248, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-34171828

RESUMO

Occupational exposure to microorganisms can be associated with adverse health outcomes. In this study, we assessed exposure to bioaerosols in two biowaste pretreatment plants in Denmark, which differed in location (city or countryside) and how they were built ('closed-off processes' or 'open processes'). Bioaerosol exposures were characterized by microbial concentrations in personal, stationary, sedimented dust, and hand samples, and their size distribution was assessed. Furthermore, species were identified by matrix-assisted laser desorption-ionisation time-of-flight mass spectrometry (MALDI-TOF MS), and inhalable dust, endotoxin, biofilm production, the total inflammatory potential, and fungicide resistance to four fungicides (amphotericin B, caspofungin acetate, itraconazole, voriconazole) were determined. Bacterial and fungal concentrations were on average (GM) in the order of 104 cfu/m3, but ranged from 102 to 108 cfu/m3. Several species which may cause health problems were identified. Personal endotoxin exposures were on average 28 EU/m3, but both personal and stationary samples ranged from 0.6 to 2035 EU/m3. Bioaerosols had the potential to form biofilms and to induce inflammation as measured in a human cell line. Exposures were higher in the plants that outdoor reference values. Higher exposures were found in the 'open process' plant, such as in microbial concentrations, species richness, endotoxin, biofilm production, and the total inflammatory potential. Six out of 28 tested Aspergillus fumigatus isolates were resistant to fungicides (amphotericin B and voriconazole). In conclusion, there is a high exposure to bioaerosols during work in biowaste pretreatment plants, however, results also suggests that how the plant is built and functions may affect the exposures.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Saúde Ocupacional , Microbiologia do Ar , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Monitoramento Ambiental , Humanos , Exposição Ocupacional/análise
18.
Sci Total Environ ; 791: 148287, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34139489

RESUMO

In many countries, the management of household waste has recently changed with an increased focus upon waste sorting resulting in lower collection frequency for some waste fractions. A consequence of this is the potential for increased growth of microorganisms in the waste before collection, which can lead to an increased exposure via inhalation for waste collection workers. Through a review of the literature, we aimed to evaluate risks caused by waste collecting workers' exposure to bioaerosols and to illuminate potential measures to reduce the exposure. Across countries and waste types, median exposure to fungi, bacteria, and endotoxin were typically around 104 colony forming units (cfu)/m3, 104 cfu/m3, and 10 EU/m3, respectively. However, some studies found 10-20+ times higher or lower median exposure levels. It was not clear how different types of waste influence the occupational exposure levels. Factors such as high loading, ventilation in and cleaning of drivers' cabs, increased collection frequency, waste in sealed sacks, and use of hand sanitizer reduce exposure. Incidences of gastrointestinal problems, irritation of the eye and skin and symptoms of organic dust toxic syndrome have been reported in workers engaged in waste collection. Several studies reported a correlation between bioaerosol exposure level and reduced lung function as either a short or a long term effect; exposure to fungi and endotoxin is often associated with an inflammatory response in exposed workers. However, a better understanding of the effect of specific microbial species on health outcomes is needed to proceed to more reliable risk assessments. Due to the increasing recycling effort and to the effects of global warming, exposure to biological agents in this working sector is expected to increase. Therefore, it is important to look ahead and plan future measures as well as improve methods to prevent long and short-term health effects.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Microbiologia do Ar , Poluentes Ocupacionais do Ar/análise , Bactérias , Poeira/análise , Endotoxinas/análise , Fungos , Humanos , Exposição Ocupacional/análise
19.
Sci Total Environ ; 788: 147832, 2021 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-34034170

RESUMO

Different types of pots and growing and casing media, including biodegradable materials, are used for plant and mushroom production. The fungus Peziza ostracoderma has gained attention for its visible growth on growing media for plants and casing media for mushrooms. Through a review of the literature we aim to evaluate whether exposure to fungi from recyclable pots and different growing and casing media occurs and causes occupational health effects. Based on the published papers, specific fungal species were not related to a specific medium. Thus P. ostracoderma has been found on paper pots, peat, sterilized soil, vermiculite, and rockwool with plants, and on peat, pumice, and paper casing for mushrooms. It has been found in high concentrations in the air in mushroom farms. Also Acremonium spp., Aspergillus niger, A. fumigatus, Athelia turficola, Aureobasidium pullulans, Chaetomium globosum, Chrysonilia sitophila, Cladosporium spp., Cryptostroma corticale, Lecanicillium aphanocladii, Sporothrix schenckii, Stachybotrys chartarum, and Trichoderma spp. have been found on different types of growing or casing media. Most of the fungi have also been found in the air in greenhouses, but the knowledge about airborne fungal species in mushroom farms is very limited. Eight publications describe cases of health effects associated directly with exposure to fungi from pots or growing or casing media. These include cases of hypersensitivity pneumonitis caused by exposure to: A. fumigatus, A. niger, Au. pullulans, Cr. corticale, P. ostracoderma, and a mixture of fungi growing on different media. Different approaches have been used to avoid growth of saprophytes including: chemical fungicides, the formulation of biodegradable pots and growing media and types of peat. To increase the sustainability of growing media different types of media are tested for their use and with the present study we highlight the importance of also considering the occupational health of the growers who may be exposed to fungi from the media and pots.


Assuntos
Fungos , Exposição Ocupacional , Ascomicetos , Chaetomium , Hypocreales , Neurospora , Exposição Ocupacional/efeitos adversos , Sporothrix , Stachybotrys
20.
Artigo em Inglês | MEDLINE | ID: mdl-33820768

RESUMO

Aspergillus niger is an opportunistic pathogen commonly found in a variety of indoor and outdoor environments. An environmental isolate of A. niger from a pig farm was resistant to itraconazole, and in-depth investigations were conducted to better understand cellular responses that occur during growth when this pathogen is exposed to an antifungal. Using a combination of cultivation techniques, antibiotic stress testing, and label-free proteomics, this study investigated the physiological and metabolic responses of A. niger to sublethal levels of antifungal stress. Challenging A. niger with itraconazole inhibited growth, and the MIC was estimated to be > 16 mg · liter-1 Through the proteome analysis, 1,305 unique proteins were identified. During growth with 2 and 8 mg · liter-1 itraconazole, a total of 91 and 50 proteins, respectively, were significantly differentially expressed. When challenged with itraconazole, A. niger exhibited decreased expression of peroxidative enzymes, increased expression of an ATP-binding cassette (ABC) transporter most likely involved as an azole efflux pump, and inhibited ergosterol synthesis; however, several ergosterol biosynthesis proteins increased in abundance. Furthermore, reduced expression of proteins involved in the production of ATP and reducing power from both the tricarboxylic acid (TCA) and glyoxylate cycles was observed. The mode of action of triazoles in A. niger therefore appears more complex than previously anticipated, and these observations may help highlight future targets for antifungal treatment.


Assuntos
Aspergillus niger , Itraconazol , Animais , Antifúngicos/farmacologia , Azóis , Farmacorresistência Fúngica/genética , Itraconazol/farmacologia , Testes de Sensibilidade Microbiana , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...